Blood profile of implantation stainless steel 316L local implant material on rat femoral bone

Show simple item record

dc.contributor en-US
dc.creator Gustian, .; Institut Pertanian Bogor
dc.creator Soehartono, H.; Faculty of Veterinary Medicine, Bogor Agricultural University
dc.creator Jujur, N.; Center for Technology Services, Agency for the Assessment and Application of Technology
dc.creator Wargadipura, A.H. S.; Center for Technology Services, Agency for the Assessment and Application of Technology
dc.creator Noviana, D.; Faculty of Veterinary Medicine, Bogor Agricultural University
dc.date 2018-09-20
dc.date.accessioned 2019-10-09T09:38:59Z
dc.date.available 2019-10-09T09:38:59Z
dc.identifier http://medpub.litbang.pertanian.go.id/index.php/jitv/article/view/1836
dc.identifier 10.14334/jitv.v23i3.1836
dc.identifier.uri http://124.81.126.59/handle/123456789/7480
dc.description This study was aimed to obtain information regarding complete blood count (CBC) profile of post implantation of stainless steel (SS) 316L as an Indonesian local product of non-degradable metal implant. Thirty adult male rat, aged approximately 12 weeks were divided into 3 groups, i.e. control group without implantation, implant group with import SS316L and implant group with Indonesian national local SS316L that developed by Agency for the Assessment and Application of Technology (BPPT). The implant groups were given implants by inserting it between femoral bone and biceps femoris muscle. On the control group, defect was made on bone without inserting an implants material. Examination of the systemic response was done with CBC before and 30 days after implantation. The analysis of red blood cells amount, haemoglobin level, haematocrite value, mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), total white blood cell and its differentiation from each group did not show significant differences. In conclusion, stainless steel 316L of import and national local product showed non-negative effects on blood profile. en-US
dc.format application/pdf
dc.language eng
dc.publisher Indonesian Center for Animal Research and Development (ICARD) en-US
dc.relation http://medpub.litbang.pertanian.go.id/index.php/jitv/article/view/1836/pdf%3D
dc.relation http://medpub.litbang.pertanian.go.id/index.php/jitv/article/downloadSuppFile/1836/73
dc.rights Copyright (c) 2018 Indonesian Journal of Animal and Veterinary Sciences en-US
dc.source Jurnal Ilmu Ternak dan Veteriner; Vol 23, No 3 (2018): SEPTEMBER 2018; 123-129 en-US
dc.source 2252-696X
dc.source 0853-7380
dc.subject Stainless Steel; Metal Implant; Biocompatibility; Blood Profile; Foreign Body Reaction en-US
dc.title Blood profile of implantation stainless steel 316L local implant material on rat femoral bone en-US
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/publishedVersion
dc.type Peer-reviewed Article en-US